Skip to content

Fluke T6-600 600V 200A Electrical Tester

by Fluke
SKU: FLUT6600
Sold out
Original price $429.00 - Original price $429.00
Original price
$429.00
$429.00 - $429.00
Current price $429.00

We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*

Features:

  • Be safer: Measure voltage to 600 V ac through the open fork, without test leads.
  • Be faster: No need to open covers or remove wire nuts.
  • Be more efficient: Simultaneously measure voltage and current.
  • Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
  • Go beyond simple detection. Actually measure ac voltage and current values without test leads.

Specifications:

  • FieldSense ac voltage true-rms 
    • Requires test leads: No
    • Range: 600 V
    • Resolution: 1 V
    • Accuracy: ±(3% + 3 counts) 45 Hz - 66 Hz[2] [3]
  • FieldSense ac current true-rms 
    • Requires test leads: No 
    • Range: 200.0 A
    • Resolution: 0.1 A
    • Accuracy: ±(3% + 3 counts) 45 Hz - 66 Hz
  • FieldSense Frequency:
    • Requires test leads: No
    • Resolution: 1 Hz
    • Accuracy: ±(1% + 2 counts)[3]
    • Volts ac true-rms
      • Requires test leads: Yes
      • Range: 600 V
      • Resolution: 1 V
      • Accuracy: ±(1.5% + 2 counts) 45 Hz - 66 Hz
    • Volts dc 
      • Requires test leads: Yes
      • Range: 600 V
      • Resolution: 1 V
      • Accuracy: ±(1% + 2 counts)
    • Resistance
      • Requires test leads: Yes
      • Range: 2000 Ω
      • Resolution: 1 Ω
      • Accuracy: ±(1% + 2 counts)
    • Safety : 600 V CAT III
    • Calibration: 1-year calibration cycle
    • Dimensions: 61.1 x 259.3 x 43.8 mm
    • Jaw opening: 17.8 mm
    • Weight: 0.35 kg (0.78 lb)
    • Temperature Operating: -10 °C to +50 °C (14 °F to 122 °F)
    • Storage: -30 °C to +60 °C (-22 °F to +140 °F)
    • Altitude Operating: 2,000 m (6,562 feet)
    • Storage: 10,000 m (32,808 feet)
    • Relative Humidity:
      • 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
      • 0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
      • 0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
    • Battery Type and Life: 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
    • Temperature coefficient:
      • 0.1 x (specified accuracy) / °C for <18°C or >28 °C
      • (< 64.4 °F or > 82.4 °F)
    • Safety: IEC/EN 61010-1: Pollution Degree 2
    • Electromagnetic Environment: IEC/EN 61326-1: Portable

    Includes:

    • Attached test leads with removable 4 mm probe caps, user documentation