Features:

A solid, reliable, basic installation tester

  • Tests voltage and frequency
  • Checks wiring polarity to detect broken N wires
  • Measures insulation resistance and loop and line resistance
  • Measures motor windings with continuity test
  • Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)

Specifications:

  • AC voltage measurement
    • Range: 500 V
    • Resolution: 0.1 V
    • Accuracy: 45 Hz – 66 Hz 0.8% + 3
    • Input impedance: 360 kΩ
    • Overload protection: 660 V rms
  • Continuity testing (RLO)
    • Range (autoranging): 20 Ω / 200 Ω / 2000 Ω
    • Resolution: 0.01 Ω / 0.1 Ω / 1 Ω
    • Open Circuit Voltage: >4 V
  • Insulation resistance measurement (RISO)
    • Accuracy of tTest voltage (at rated test current): +10%, -0%
    • Test voltage
      • 100 V
      • 250 V
      • 500 V
      • 1000 V
    • Insulation resistance range
      • 20 MΩ / 50 MΩ
      • 20 MΩ / 100 MΩ
      • 20 MΩ / 200 MΩ
      • 20 MΩ / 200 MΩ / 500 MΩ
      • 20 MΩ / 200 MΩ / 1000 MΩ
    • Resolution
      • 0.01 MΩ / 0.1 MΩ
      • 0.01 MΩ / 0.1 MΩ
      • 0.01 MΩ / 0.1 MΩ
      • 0.01 MΩ / 0.1 MΩ / 1 MΩ
      • 0.01 MΩ / 0.1 MΩ / 1 MΩ
    • Test current
      • 1 mA @ 50 kΩ
      • 1 mA @ 100 kΩ
      • 1 mA @ 250 kΩ
      • 1 mA @ 500 kΩ
      • 1 mA @ 1 MΩ
  • Loop and line impedance (ZI)
    • Range: 10 Ω / 0.001 Ω / High current mΩ mode
    • Resolution: 0.01 Ω / 0.1 Ω / 1 Ω
  • Prospective earth fault current, PSC test
    • Range: 1000 A / 10 kA (50 kA)
    • Resolution: 1 A / 0.1 kA
    • Computation: Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
  • RCD testing, RCD types tested
    • RCD Type: A4, AC¹, G², S³
    • Notes:
      • ¹Responds to AC
      • ²General, no delay
      • ³Time delay
      • 4Responds to pulsed signal
      • 5Responds to smooth DC signal
  • Tripping speed test (ΔT)
    • Current settings¹:
      • 10-30-100-300-500-1000 mA – VAR
      • 10-30-100 mA
    • Multiplier:
      • x ½, x 1
      • x 5
    • Measurement range
      • RCD Type G 310 ms
        • 50 ms
      • RCD Type S 510 ms
        • 160 ms
    • Notes:
      • ¹1000 mA type AC only
      • 700 mA maximum type A in VAR mode
      • VAR mode not available for type B.
  • RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
    • Current range: 30% to 110% of RCD rated current¹
    • Step size: 10% of IΔN²
    • Dwell time:
      • Type G 300 ms/step
      • Type S 500 ms/step
    • Measurement accuracy: ±5%
    • Specified trip current ranges (EN 61008-1)
      • 50% to 100% for Type AC
      • 35% to 140% for Type A (>10 mA)
      • 35% to 200% for Type A (≤10 mA)
      • 50% to 200% for Type B
      • ²5% for Type B
    • Notes
      • ¹30% to 150% for Type A IΔN > 10 mA
      • 30% to 210% for Type A IΔN = 10 mA
      • 20% to 210% for Type B
  • Phase Sequence Indication
    • Icon: icon phase sequence indicator Phase Sequence indicator is active.
  • Size (L x W x H): 10 x 25 x 12.5 cm
  • Weight (incl. batteries): 1.3 Kg
  • Battery size, quantity: Type AA, 6 ea.
  • Sealing: IP-40
  • Safety: Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
  • Overvoltage: CAT III / 500V; CAT IV 300V
  • Performance: EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

Includes:

  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • C1600 hard carrying case
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead