Fluke FLK-1662-AU Multi-Function Multimeter Tester with Memory
by Fluke
SKU: FLK-1662-AU
Sold out
Original price
$2,383.70
-
Original price
$2,383.70
Original price
$2,383.70
$2,383.70
-
$2,383.70
Current price
$2,383.70
Features:
A solid, reliable, basic installation tester
- Tests voltage and frequency
- Checks wiring polarity to detect broken N wires
- Measures insulation resistance and loop and line resistance
- Measures motor windings with continuity test
- Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
Specifications:
- AC voltage measurement
- Range: 500 V
- Resolution: 0.1 V
- Accuracy: 45 Hz – 66 Hz 0.8% + 3
- Input impedance: 360 kΩ
- Overload protection: 660 V rms
- Continuity testing (RLO)
- Range (autoranging): 20 Ω / 200 Ω / 2000 Ω
- Resolution: 0.01 Ω / 0.1 Ω / 1 Ω
- Open Circuit Voltage: >4 V
- Insulation resistance measurement (RISO)
- Accuracy of tTest voltage (at rated test current): +10%, -0%
- Test voltage
- 100 V
- 250 V
- 500 V
- 1000 V
- Insulation resistance range
- 20 MΩ / 50 MΩ
- 20 MΩ / 100 MΩ
- 20 MΩ / 200 MΩ
- 20 MΩ / 200 MΩ / 500 MΩ
- 20 MΩ / 200 MΩ / 1000 MΩ
- Resolution
- 0.01 MΩ / 0.1 MΩ
- 0.01 MΩ / 0.1 MΩ
- 0.01 MΩ / 0.1 MΩ
- 0.01 MΩ / 0.1 MΩ / 1 MΩ
- 0.01 MΩ / 0.1 MΩ / 1 MΩ
- Test current
- 1 mA @ 50 kΩ
- 1 mA @ 100 kΩ
- 1 mA @ 250 kΩ
- 1 mA @ 500 kΩ
- 1 mA @ 1 MΩ
- Loop and line impedance (ZI)
- Range: 10 Ω / 0.001 Ω / High current mΩ mode
- Resolution: 0.01 Ω / 0.1 Ω / 1 Ω
- Prospective earth fault current, PSC test
- Range: 1000 A / 10 kA (50 kA)
- Resolution: 1 A / 0.1 kA
- Computation: Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
- RCD testing, RCD types tested
- RCD Type: A4, AC¹, G², S³
- Notes:
- ¹Responds to AC
- ²General, no delay
- ³Time delay
- 4Responds to pulsed signal
- 5Responds to smooth DC signal
- Tripping speed test (ΔT)
- Current settings¹:
- 10-30-100-300-500-1000 mA – VAR
- 10-30-100 mA
- Multiplier:
- x ½, x 1
- x 5
- Measurement range
- RCD Type G 310 ms
- 50 ms
- RCD Type S 510 ms
- 160 ms
- Notes:
- ¹1000 mA type AC only
- 700 mA maximum type A in VAR mode
- VAR mode not available for type B.
- RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
- Current range: 30% to 110% of RCD rated current¹
- Step size: 10% of IΔN²
- Dwell time:
- Type G 300 ms/step
- Type S 500 ms/step
- Measurement accuracy: ±5%
- Specified trip current ranges (EN 61008-1)
- 50% to 100% for Type AC
- 35% to 140% for Type A (>10 mA)
- 35% to 200% for Type A (≤10 mA)
- 50% to 200% for Type B
- ²5% for Type B
- Notes
- ¹30% to 150% for Type A IΔN > 10 mA
- 30% to 210% for Type A IΔN = 10 mA
- 20% to 210% for Type B
- Phase Sequence Indication
- Icon: icon phase sequence indicator Phase Sequence indicator is active.
- Size (L x W x H): 10 x 25 x 12.5 cm
- Weight (incl. batteries): 1.3 Kg
- Battery size, quantity: Type AA, 6 ea.
- Sealing: IP-40
- Safety: Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
- Overvoltage: CAT III / 500V; CAT IV 300V
- Performance: EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition
Includes:
- 6x AA (IEC LR6) cell batteries
- C1600 hard carrying case
- Zero adapter
- Heavy duty mains cord
- STD standard test lead set
- C1600 hard carrying case
- Padded carrying and waist strap
- Quick reference guide
- TP165X remote control probe and lead
- User's manual on CD-ROM