Fluke T6-600 600V 200A Electrical Tester
by Fluke
SKU: FLUT6600
Original price
$429.00
-
Original price
$429.00
Original price
$429.00
$429.00
-
$429.00
Current price
$429.00
We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*
Features:
- Be safer: Measure voltage to 600 V ac through the open fork, without test leads.
- Be faster: No need to open covers or remove wire nuts.
- Be more efficient: Simultaneously measure voltage and current.
- Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
- Go beyond simple detection. Actually measure ac voltage and current values without test leads.
Specifications:
- FieldSense ac voltage true-rms
- Requires test leads: No
- Range: 600 V
- Resolution: 1 V
- Accuracy: ±(3% + 3 counts) 45 Hz - 66 Hz[2] [3]
- FieldSense ac current true-rms
- Requires test leads: No
- Range: 200.0 A
- Resolution: 0.1 A
- Accuracy: ±(3% + 3 counts) 45 Hz - 66 Hz
- FieldSense Frequency:
- Requires test leads: No
- Resolution: 1 Hz
- Accuracy: ±(1% + 2 counts)[3]
- Volts ac true-rms
- Requires test leads: Yes
- Range: 600 V
- Resolution: 1 V
- Accuracy: ±(1.5% + 2 counts) 45 Hz - 66 Hz
- Volts dc
- Requires test leads: Yes
- Range: 600 V
- Resolution: 1 V
- Accuracy: ±(1% + 2 counts)
- Resistance
- Requires test leads: Yes
- Range: 2000 Ω
- Resolution: 1 Ω
- Accuracy: ±(1% + 2 counts)
- Safety : 600 V CAT III
- Calibration: 1-year calibration cycle
- Dimensions: 61.1 x 259.3 x 43.8 mm
- Jaw opening: 17.8 mm
- Weight: 0.35 kg (0.78 lb)
- Temperature Operating: -10 °C to +50 °C (14 °F to 122 °F)
- Storage: -30 °C to +60 °C (-22 °F to +140 °F)
- Altitude Operating: 2,000 m (6,562 feet)
- Storage: 10,000 m (32,808 feet)
- Relative Humidity:
- 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
- 0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
- 0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
- Battery Type and Life: 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
- Temperature coefficient:
- 0.1 x (specified accuracy) / °C for <18°C or >28 °C
- (< 64.4 °F or > 82.4 °F)
- Safety: IEC/EN 61010-1: Pollution Degree 2
- Electromagnetic Environment: IEC/EN 61326-1: Portable
Includes:
- Attached test leads with removable 4 mm probe caps, user documentation