Features:

The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke v3000 FC Wireless AC Voltage Module offers:

  • Measurements up to 1000 V true-RMS AC
  • Use as a standalone meter or as part of the system
  • A logging function for recording and saving up to 65,000 readings

The Fluke v3001 FC Wireless DC Voltage Module lets you:

  • Measure up to 1000 V DC
  • Use as a standalone meter or as part of the system
  • Use the logging function for recording and saving up to 65,000 readings

The Fluke a3001 FC Wireless iFlex® AC Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:

  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function

Specifications:

  • Fluke 3000 FC Series Wireless Multimeter
    • AC Voltage: 
      • Range¹ / resolution:
        • 600.0 mV / 0.1 mV
        • 6.000 V / 0.001 V
        • 60.00 V / 0.01 V
        • 600.0 V / 0.1 V
        • 1000 V / 1 V
      • Accuracy234 :
        • 45 Hz to 500 Hz 1.0% + 3
        • 500 Hz to 1 kHz 2.0% + 3
    • mV
      • Range / resolution: 600.0 mV / 0.1 mV
      • Accuracy 0.09% + 2
    • V
      • Range / resolution
        • 6.000 V / 0.001 V
        • 60.00 V / 0.01 V
        • 600.0 V / 0.1 V
        • 1000 V / 1 V
      • Accuracy
        • 0.09% + 2
        • 0.15% + 2
    • )))
      • Range / resolution: 600 Ω / 1 Ω
      • Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    • Ω
      • Range / resolution
        • 600.0 Ω / 0.1 Ω
        • 6.000 kΩ / 0.001 kΩ
        • 60.00 kΩ / 0.01 kΩ
        • 60.00 kΩ / 0.1 kΩ
        • 600.0 kΩ / 0.001 MΩ
        • 50.00 MΩ / 0.01 MΩ
      • Accuracy 0.5% + 2
        • 0.5% + 1
        • 1.5% + 3
    • Diode test
      • Range / resolution: 2.000 V / 0.001 V
      • Accuracy: 1% + 2
    • µF
      • Range / resolution
        • 1000 nF / 1 nF
        • 10.00 μF / 0.01 μF
        • 100.0 μF / 0.1 μF
        • 9999 μF1 / 1 μF
      • Accuracy:
        • 1.2% + 2
        • 10% typical
    • mA AC (45 Hz to 1 kHz)
      • Range1 / resolution
        • 60.00 mA / 0.01 mA
        • 400.0 mA3 / 0.1 mA
      • Accuracy: 1.5% + 3
    • mA DC2
      • Range1 / resolution:
        • 60.00 mA / 0.01 mA
        • 400.0 mA3 / 0.1 mA
      • Accuracy: 0.5% + 3
    • Frequency
      • Range / resolution:
        • 99.99 Hz / 0.01 Hz
        • 999.9 Hz / 0.1 Hz
        • 9.999 kHz / 0.001 kHz
        • 99.99 kHz / 0.01 kHz
      • Accuracy1 :0.1% + 1
    • mA Function
      • Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
      • Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    • MIN/MAX Recording Accuracy
      • DC functions: ± 12 counts for changes > 350 mS in duration.
      • AC functions: ± 40 counts for changes > 900 mS in duration.
    • Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS
    • Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    • Display (LCD):
      • Update rate: 4/sec
      • Volts, amps, ohms: 6000 counts
      • Frequency: 10,000 counts
    • Capacitance: 1,000 counts
    • Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6
    • Battery life: 250 hours minimum
    • RF communications: 2.4 GHZ ISM Band
    • RF communication range: Open air, unobstructed Up to 20m
    • Obstructed, sheetrock wall: Up to 6.5m
    • Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
    • Temperature:
      • Operating: -10°C to 50°C
      • Storage: -40°C to 60°C
    • Temperature coefficient: 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
    • Relative humidity:
      • 0% to 90% (0°C to 35°C)
      • 0% to 75% (35°C to 40°C)
      • 0% to 45% (40°C to 50°C)
    • Altitude Operating: 2,000 m
    • Storage: 12,000 m
    • Electromagnetic compatibility EMI, RFI, EMC, RF
      • EN 61326–1:2006, EN 61326–2–2:2006
      • ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
      • V1.8.1:2008
      • FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
      • FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
    • Safety compliance:
      • ANSI / ISA 61010–1 / (82.02.01): 3rd edition
      • CAN / CSA-C22.2 No 61010-1-12: 3rd edition
      • UL 61010–1: 3rd edition
      • IEC / EN 61010–1:2010
    • Certifications: CSA, FCC, CE
    • Ingress Protection (IP) rating: IP54
    • Pollution Degree: 2
    • Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    • Weight: 340 g (12 oz)
    • Warranty: Three years

* Not compatible with Fluke CNX test tools

  • Fluke v3000 FC Wireless AC Voltage Module
    • Range¹ / Resolution
      • 6.000 V / 0.001 V
      • 60.00 V / 0.01 V
      • 600.0 V / 0.1 V
      • 1000 V / 1 V
    • Accuracy234 :
      • 45 Hz to 500 Hz / 1.0% + 3
      • 500 Hz to 1 kHz / 2.0% + 3
    • LCD w/backlight: 3½ digits, 6000 counts, updates 4/sec
    • Battery type: 2 AA, NEDA 15 A, IEC LR6
    • Battery life: 400 Hours
    • Memory Record: up to 65000 readings
    • RF communications: 2.4 GHZ ISM Band
    • RF communication range
      • Open air, unobstructed Up to 20 m
      • Obstructed, sheetrock wall Up to 6.5 m
      • Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    • Operating temperature: -10°C to +50°C
    • Storage temperature: -40°C to +60°C
    • Temperature coefficient: 0.1 X (specified accuracy)/°C (< 18°C or > 28°C)
    • Operating humidity: 90% at 35°C, 45% at 40°C, 45% at 50°C
    • Altitude
      • Operating 2,000 m
      • Storage 12,000 m
    • EMC EN 61326–1:2006
    • Safety compliance
      • ANSI/ISA 61010–1 / (82.02.01) 3rd edition
      • CAN / CSA–C22.2 No 61010–1–12 3rd edition
      • UL 61010–1 3rd edition
      • IEC/EN 61010–1 2010
    • Safety rating: CAT IV 600 V, CAT III 1000 V
    • Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    • Ingress Protection (IP) rating: IP42
    • Pollution Degree: 2
    • Size (HxWxD): 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    • Weight: .22 kg (8 oz)
    • Warranty: Three years

Note: Not compatible with Fluke CNX test tools

  • Fluke v3001 FC Wireless DC Voltage Module
    • mV DC
      • Range¹ / resolution: 600.0 mV / 0.1 mV
      • Accuracy: 0.09% + 3
    • VDC
      • Range¹ / resolution
        • 6.000 V / 0.001 V
        • 60.00 V / 0.01 V
        • 600.0 V / 0.1 V
      • Accuracy: 0.09% + 3
      • Range¹ / resolution: 1000 V / 1 V
      • Accuracy: 0.15% + 2
    • LCD w/ backlight: 3 ½ digits, 6000 counts, 4/sec update rate
    • Battery type: 2 AA Alkaline batteries, NEDA 15A, IEC LR6
    • Log rate/interval: Adjustable by PC from 1 sec to 1 hr, default 1 min
    • Battery life: 400 hours minimum
    • Memory Record: up to 65,000 readings
    • RF communications: 2.4 GHz ISM Band
    • RF communication range: Open air, unobstructed Up to 20 m
    • Obstructed, sheetrock wall: Up to 6.5 m
    • Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
    • Operating temperature: -10°C to +50°C
    • Storage temperature: -40°C to +60°C
    • Temperature coefficient: 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    • Relative humidity:
      • 0% to 90% (0°C to 35°C), 0% to 75% (35°C to 40°C),
      • 0% to 45% (40°C to 50°C)
    • EMC: IEC 61236–1, Portable
    • Safety compliance: IEC 61010–1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2
    • Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    • Ingress Protection (IP) rating: IP42
    • Size (H x W x D): 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
    • Weight: 0.255 kg (9 oz)
    • Warranty: Three years

* Not compatible with Fluke CNX test tools

  • Fluke a3001 FC Wireless iFlex® AC Current Module
    • Range: 0.5 A to 2500 A AC
    • Resolution: 0.1 A
    • Accuracy: 3% ± 5 digits (5 Hz to 500 Hz)
    • Crest factor: (50 Hz/60 Hz)
      • 3.0 at 1100 A
      • 2.5 at 1400 A
      • 1.42 at 2500 A
      • Add 2% for C.F. > 2
    • LCD w/backlight: 3½ digits
    • Log rate/interval: 1 sec minimum/adjustable by PC or front panel
    • Battery type: 2 AA, NEDA 15 A, IEC LR6
    • Battery life: 400 hours
    • Memory Record: up to 65,000 readings
    • RF communications: 2.4 GHZ ISM Band
    • RF communication range:
      • Open air, unobstructed: Up to 20 m
      • Obstructed, sheetrock wall: Up to 6.5 m
      • Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
    • Operating temperature: -10°C to +50°C
    • Storage temperature: -40°C to +60°C
    • Temperature coefficient: Add 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
    • Operating humidity:
      • 90% at 35°C
      • 75% at 40°C
      • 45% at 50°C
    • Altitude Operating: 2,000 m
    • Storage: 12,000 m
    • EMC: EN 61326-1:2006
    • Safety: compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
    • Safety rating: CAT IV 600 V, CAT III 1000 V
    • Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    • Ingress Protection (IP) rating: IP42
    • Pollution Degree: 2
    • Jaw opening: 25.4 cm (10 in) coil
    • Size (HxWxD): 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
    • Weight: .22 kg (8 oz)
    • Warranty: Three years

* Note: Not compatible with Fluke CNX test tools

Includes:

  • Fluke 3000 FC Series Wireless Multimeter
  • Fluke v3000 Voltage Module
  • Fluke v3001 Voltage Module
  • Fluke a3001 FC Wireless iFlex AC Current Module
  • TL224 Test Leads
  • TL222 Test Leads
  • TL175 Test Leads
  • AC285 Alligator Clips
  • AC220 Alligator Clips
  • AC175 Alligator Clips
  • iFlex i2500-10 Flexible Current Probe
  • Magnetic hanging strap