Fluke FLK-3000 FC IND FC Wireless Industrial System
Features:
The Fluke 3000 FC Industrial System provides measurement of all common electrical parameters
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:
- AC and DC voltage measurements to 1000 V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
The Fluke v3000 FC Wireless AC Voltage Module offers:
- Measurements up to 1000 V true-RMS AC
- Use as a standalone meter or as part of the system
- A logging function for recording and saving up to 65,000 readings
The Fluke a3001 FC Wireless iFlex® AC Current Module allow you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:
- Measure up to 2500 A AC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
Specifications:
- Fluke 3000 FC Series Wireless Multimeter
- AC Voltage
- Range ¹ / Resolution
- 600.0 mV / 0.1 mV
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- Accuracy 234 :
- 45 Hz to 500 Hz 1.0% + 3
- 500 Hz to 1 kHz 2.0% + 3
- DC Voltage, Continuity, Resistance, Diode Test and Capacitance
- mV
- Range / Resolution: 600.0 mV / 0.1 mV
- Accuracy: 0.09% + 2
- V
- Range / Resolution
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- Accuracy
- 0.09% + 2
- 0.15% + 2
- )))
- Range / Resolution: 600 Ω / 1 Ω
- Accuracy: Meter beeps at
- Ω
- Range / Resolution
- 600.0 Ω / 0.1 Ω
- 6.000 kΩ / 0.001 kΩ
- 60.00 kΩ / 0.01 kΩ
- 60.00 kΩ / 0.1 kΩ
- 600.0 kΩ / 0.001 MΩ
- 50.00 MΩ / 0.01 MΩ
- Accuracy
- 0.5% + 2
- 0.5% + 1
- 1.5% + 3
- Diode test
- Range / Resolution: 2.000 V / 0.001 V
- Accuracy: 1% + 2
- µF
- Range / Resolution
- 1000 nF / 1 nF
- 10.00 μF / 0.01 μF
- 100.0 μF / 0.1 μF
- 9999 μF1 / 1 μF
- Accuracy:
- 1.2% + 2
- 10% typical
- AC and DC Current
- mA AC (45 Hz to 1 kHz)
- Range 1 / Resolution
- 60.00 mA / 0.01 mA
- 400.0 mA 3/ 0.1 mA
- Accuracy 1.5% + 3
- mA DC 2
- Range 1 / Resolution
- 60.00 mA / 0.01 mA
- 400.0 mA 3/ 0.1 mA
- Accuracy 0.5% + 3
- Frequency
- Range / Resolution
- 99.99 Hz / 0.01 Hz
- 999.9 Hz / 0.1 Hz
- 9.999 kHz / 0.001 kHz
- 99.99 kHz / 0.01 kHz
- Accuracy 1 0.1% + 1
- mA Function
- Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
- Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
- MIN/MAX Recording Accuracy
- DC functions: The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
- AC functions: The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
- Maximum voltage between any terminal and earth ground: 1000 VDC or AC rms
- Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
- Display (LCD)
- Update rate: 4/sec
- Volts, amps, ohms: 6000 counts
- Frequency: 10,000 counts
- Capacitance: 1,000 counts
- Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6
- Battery life: 250 hours minimum
- RF communications: 2.4 GHZ ISM Band
- RF communication range:
- Open air, unobstructed Up to 20 m
- Obstructed, sheetrock wall Up to 6.5 m
- Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
- TemperatureL
- Operating: -10°C to 50°C
- Storage: -40°C to 60°C
- Temperature coefficient: 0.1 x (specified accuracy) / °C ( 28°C)
- Relative humidity:
- 0% to 90% (0°C to 35°C)
- 0% to 75% (35°C to 40°C)
- 0% to 45% (40°C to 50°C)
- Altitude Operating: 2,000 m
- Storage: 12,000 m
- Electromagnetic compatibility
- EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
- ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
- V1.8.1:2008,
- FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
- FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
- Safety compliance:
- ANSI/ISA 61010-1 / (82.02.01): 3rd edition
- CAN/CSA-C22.2 No 61010-1-12: 3rd edition
- UL 61010-1: 3rd edition
- IEC/EN 61010-1:2010
- Certifications: CSA, FCC, CE
- Ingress Protection (IP) rating: IP54
- Pollution Degree: 2
- Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
- Weight: 340 g (12 oz)
- Warranty: Three years
- Fluke a3001 FC Wireless iFlex AC Current Module
- Range: 0.5 A to 2500 A AC
- Resolution: 0.1 A
- Accuracy: 3% ±5 digits (5 Hz to 500 Hz)
- Crest factor (50 Hz/60 Hz):
- 3.0 at 1100 A
- 2.5 at 1400 A
- 1.42 at 2500 A
- add 2% for C.F. > 2
- LCD w/ backlight: 3½ digits
- Log rate/interval: 1 sec minimum/adjustable by PC or front panel
- Battery type: 2 AA, NEDA 15 A, IEC LR6
- Battery life: 400 hours
- Memory Record: up to 65,000 readings
- RF communications: 2.4 GHZ ISM Band
- RF communication range:
- Open air, unobstructed Up to 20 m
- Obstructed, sheetrock wall Up to 6.5 m
- Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
- Operating temperature: -10°C to +50°C
- Storage temperature: -40°C to +60°C
- Temperature coefficient: Add 0.1 x (specified accuracy) / °C ( 28°C)
- Operating humidity:
- 90% at 35°C
- 75% at 40°C
- 45% at 50°C
- Altitude Operating: 2,000 m
- Storage: 12,000 m
- EMC: EN 61326-1:2006
- Safety compliance: IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
- Safety rating: CAT IV 600 V, CAT III 1000 V
- Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
- Ingress Protection (IP) rating: IP42
- Pollution Degree: 2
- Jaw opening: 25.4 cm (10 in) coil
- Size (H x W x D): 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
- Weight: .22 kg (8 oz)
- Warranty: Three years
* Not compatible with Fluke CNX test tools
- Fluke v3000 FC Wireless AC Voltage Module
- Range ¹ / Resolution:
- 6.000 V / 0.001 V
- 60.00 V / 0.01 V
- 600.0 V / 0.1 V
- 1000 V / 1 V
- Accuracy 234:
- 45 Hz to 500 Hz 1.0% + 3
- 500 Hz to 1 kHz 2.0% + 3
- LCD w/ backlight: 3½ digits, 6000 counts, updates 4/sec
- Battery type: 2 AA, NEDA 15 A, IEC LR6
- Battery life: 400 Hours
- Memory Record: up to 65000 readings
- RF communications: 2.4 GHZ ISM Band
- RF communication range
- Open air, unobstructed Up to 20 m
- Obstructed, sheetrock wall Up to 6.5 m
- Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
- Operating temperature: -10°C to +50°C
- Storage temperature: -40°C to +60°C
- Temperature coefficient: 0.1 x (specified accuracy)/ °C ( 28°C)
- Operating humidity: 90% at 35°C, 45% at 40°C, 45% at 50°C
- Altitude
- Operating: 2,000 m
- Storage: 12,000 m
- EMC: EN 61326-1:2006
- Safety compliance:
- ANSI/ISA 61010-1 / (82.02.01) 3rd edition
- CAN/CSA-C22.2 No 61010-1-12 3rd edition
- UL 61010-1 3rd edition
- IEC/EN 61010-1 2010
- Safety rating: CAT IV 600 V, CAT III 1000 V
- Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
- Ingress Protection (IP) rating: IP42
- Pollution Degree: 2
- Size (H x W x D): 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
- Weight: .22 kg (8 oz)
- Warranty: Three years
* Not compatible with Fluke CNX test tools
Includes:
- Fluke 3000 FC Series Wireless Multimeter
- Fluke a3001 FC Wireless iFlex AC Current Module (3)
- Fluke v3000 Voltage Module
- TL224 Test Leads
- TL175 Test Leads
- AC285 Alligator Clips
- AC175 Alligator Clips
- iFlex i2500-10 Flexible Current Probe (3)
- Magnetic hanging strap