Fluke I2000FLEX 2000A Flexible AC Current Clamp

by Fluke
SKU: I2000FLEX
Original price $930.60 - Original price $930.60
Original price
$930.60
$930.60 - $930.60
Current price $930.60

The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Features:

  • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600 V safety rating

Specifications:

  • Current ranges
    • 20 A
    • 200 A
    • 2000 A
    • AC rms
  • Output sensitivity (AC-coupled)
    • 1 mV
    • 10 mV
    • 100 mV
    • 1 mV per A
  • Load impedance: 100 kΩ minimum
  • Accuracy at
    • +25°C
    • ±1% of range (45 Hz to 65 Hz)
  • Linearity:
    • 10% to 100% of range
    • ±0.2% of reading
  • Noise:
    • 8 mV AC rms (30 A)
    • 2 mV AC rms (300 A, 3000 A)
  • Frequency range: 10 Hz to 20 kHz (-3 dB)
  • Phase error:
    • < ±1° (45 Hz to 65 Hz)
    • ±10° (at 20 kHz)
  • Position sensitivity:
    • with cable > 25 mm from the coupling
    • ±2% of range
  • External field:
    • with cable > 200 mm from the head
    • ±1% of range
  • Power supply: 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
  • Temperature Coefficient: ±0.08% of reading per °C
  • Working voltage:
    • see Safety standards section
    • 600 V AC rms or DC
  • Head Circumference: 610 mm (24 in)
  • Head cable diameter: 14.3 mm (0.56 in)
  • Head bend radius: 38.1 mm (1.5 in)
  • Cable length (head to electronics): 2 m (6.56 ft)
  • Output connection: Molded 4 mm safety plugs (not integrated)
  • Operating temperature range: 0°C to +70°C (32°F to 158°F) (head and electronics)
  • Storage temperature range:
    • -40°C to +105°C (-40°F to 221°F) (head)
    • -20°C to +85°C (-4°F to 185°F) (electronics)
  • Operating humidity: 15% to 85% (non-condensing)
  • Weight:
    • 180 g (6.34 oz) (head)
    • 190 g (6.70 oz) (electronics)
  • Safety standards:
    • EN 61010-031: 2002
    • EN 61010-2-032: 2002
    • EN 61010-1: 2001
    • 600 Vrms, Category III, Pollution Degree 2
    • Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
  • EMC standards: EN 61326: 1998 +A1, A2, and A3
  • Dimensions (H x W x D): 116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)