Fluke FLUKE-707EX mA Intrinsically Safe Loop Calibrator

by Fluke
FREE Shipping over $99*
Exclusions apply – See Shipping Policy
$2,536.60

Buy Now. Pay Later

Estimated Dispatch Time: 3-10 days
i

Contact us for an exact ETA. Subject to availability - T/C's apply

Fluke 707Ex for fast one-handed mA loop checks in Ex zones

The Fluke 707Ex is an intrinsically safe loop calibrator for use in potential explosive environments. The Fluke 707Ex is certified in accordance with the ATEX directive in Zones 1 and 2. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2. It is also certified to operate in accordance with Factory Mutual N.I. Class 1, Division 2 areas Group A-D.

Beyond that it combines the best features of a push-button and knob-base loop calibrator, for extremely fast and easy calibration. The large display and simple quick-click rotary button lets you make quick selections and adjustments with one hand. Plus, features such as mA sourcing, simulation and measurement; simultaneous display of mA and % of span, and selectable step or ramp outputs, helps you work more efficiently and accurately. And you can quickly change the 9V battery without breaking the calibration seal.

Features:

  • High performance intrinsically safe loop calibrator for use in potentially explosive environments
  • Is certified in accordance with ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2 and to operate in accordance with Factory Mutual N.I. Class 1, Division 2 areas Group A-D
  • Features large display and simple, quick-click interface for easy one-handed operation
  • Provides simultaneous mA and % readout for quick, easy interpretation of readings.
  • Delivers superior mA accuracy of 0.015%
  • Provides 1 ”A resolution for mA source, simulate, and measure
  • Includes HARTÂź compatible resistance connected in series with the loop supply for compatibility with HART communicators
  • Features push button 25% steps for fast, easy linearity checks
  • Includes 0-100% “span check” for fast confirmation of zero and span.
  • Provides selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
  • Includes a 24 volt internal loop supply, so you can power and read a transmitter at the same time without a DMM.
  • Measures V DC to 28 V
  • Runs on a single 9 V battery that is easily changed without breaking the calibration seal
  • Offers 0 - 20 mA or 4 - 20 mA default start up modes
  • Features an innovative output adjustment dial
  • Comes with a protective yellow holster with test lead storage and a three year warranty

Specifications:

  • Current measurement
    • Range: 0 to 24 mA
    • Resolution: 0.001 mA
    • Accuracy: 0.015% Rdg + 2 LSD
  • Current sourcing
    • Range: 0 to 20 mA or 4 to 20 mA
    • Accuracy: 0.015% Rdg + 2 LSD
    • Drive capability: 700 Ω at 20 mA
  • Current simulation
    • Range: 0 to 20 mA or 4 to 20 mA
    • Accuracy: 0.015% Rdg + 2 LSD
  • Loop power: While measuring mA, 24 V
  • Voltage measurement
    • Range: 0 to 28 V DC
    • Resolution: 1 mV
    • Accuracy: 0.015% Rdg + 2 LSD
  • Operating temperature:  -10ÂșC to 55ÂșC
  • Storage temperature: -40ÂșC to 60ÂșC
  • Humidity (without condensation)
    • 0 to 95% (0ÂșC to 30ÂșC);
    • 0 to 75% (30ÂșC to 40ÂșC)
    • 0 to 45% (40ÂșC to 50ÂșC)
  • Temperature coefficient: -10ÂșC to 18ÂșC, 28ÂșC to 55ÂșC, ±.005% of range per ÂșC
  • Safety: CSA C22.2 No. 1010.1:1992
  • EMC: EN50082-1:1992 and EN55022:1994 Class B
  • Maximum voltage 30 V
  • ATEX certification: Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X
  • CE certification: EN61010-1 and EN61326
  • Size: 152 x 70 x 41 mm
  • Weight: 224 g (350 g including holster)
  • Batteries: One 9V battery Alkaline
  • Warranty: 3 year
  • Shock & vibration: per MIL-T-28800 for a Class 2 Instrument
  • Display current and % of span: Yes
  • Auto step, auto ramp: Yes
  • Span check: Yes

Includes:

  • Alligator test clips
  • Instruction manual (on CD-ROM)
  • Protective holster with Flex-Standℱ
  • Safety designed test leads
  • NIST- traceable calibration report and data

Subscribe to our newsletter for all the latest deals!