Skip to content

Fluke 1663FVF Multi-Function Multimeter Installation Tester

by Fluke
SKU: 1663FVF
Sold out
Original price $3,212.00 - Original price $3,212.00
Original price
$3,212.00
$3,212.00 - $3,212.00
Current price $3,212.00

The 1663 installation tester delivers the full-featured functionality and advanced measurement capabilities that professional installers need. It is compact and lightweight (less than 1.3 kg) and comes with a padded carrying and waist strap for convenient handling. Operation is intuitive and easily mastered by all levels of workers so you can put it to work immediately for quick and efficient testing to all local regulations. Additional helpful features like On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.

Features:

  • Full featured tester for installation professionals
  • Tests to all local regulations and provides test results for complete documentation
  • Tests continuity at L-N, N-PE inputs
  • Tests smooth dc sensitive RCDs (Type B)
  • Tests earth resistance, voltage, and frequency
  • Offers multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
  • Checks wiring polarity to detect broken N wires
  • Measures insulation resistance and loop and line resistance
  • Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
  • Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
  • Measures motor windings with continuity test
  • Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
  • Measures RCD switching time and tripping level (ramp test)
  • Measures trip time and current for RCD type A & AC in one test
  • Measures RCD variable current
  • Provides automatic RCD test sequence
  • Includes a phase sequence indicator
  • Safety rated CAT III 500V, CAT IV 300V
  • Comes with hard carrying case, padded carrying and waist strap, and remote control probe and lead

Specifications:

  • AC voltage measurement
    • Range: 500 V
    • Resolution: 0.1 V
    • Accuracy: 45 Hz – 66 Hz 0.8% + 3
    • Input impedance: 360 kΩ
    • Overload protection: 660 V rms
  • Continuity testing (RLO)
    • Range (autoranging): 20 Ω / 200 Ω / 2000 Ω
    • Resolution: 0.01 Ω / 0.1 Ω / 1 Ω
    • Open Circuit Voltage: >4 V
  • Insulation resistance measurement (RISO)
    • Test voltages: 50-100-250-500-1000 V
    • Accuracy of tTest voltage (at rated test current): +10%, -0%
    • Test voltage:
      • 50 V
      • 100 V
      • 250 V
      • 500 V
      • 1000 V
    • Insulation resistance range
      • 20 MΩ /50 MΩ
      • 20 MΩ / 100 MΩ
      • 20 MΩ / 200 MΩ
      • 20 MΩ / 200 MΩ / 500 MΩ
      • 20 MΩ / 200 MΩ / 1000 MΩ
    • Resolution
      • 0.01 MΩ / 0.1 MΩ
      • 0.01 MΩ / 0.1 MΩ
      • 0.01 MΩ / 0.1 MΩ
      • 0.01 MΩ / 0.1 MΩ / 1 MΩ
      • 0.01 MΩ / 0.1 MΩ / 1 MΩ
    • Test current
      • 1 mA @ 50 kΩ
      • 1 mA @ 100 kΩ
      • 1 mA @ 250 kΩ
      • 1 mA @ 500 kΩ
      • 1 mA @ 1 MΩ
  • Loop and line impedance (ZI)
    • Range: 10 Ω / 0.001 Ω / High current mΩ mode
    • Resolution: 0.01 Ω / 0.1 Ω / 1 Ω
  • Prospective earth fault current, PSC test
    • Range: 1000 A / 10 kA (50 kA)
    • Resolution: 1 A / 0.1 kA
    • Computation Prospective: earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
  • RCD testing, RCD types tested
    • RCD Type:
      • AC¹
      • G²,S³
    • Model: 1663 A4, AC¹, G²,S³
    • Notes:
      • ¹Responds to AC
      • ²General, no delay
      • ³Time delay
      • 4 Responds to pulsed signal
      • 5 Responds to smooth DC signal
  • Tripping speed test (ΔT)
    • Current settings¹: 10-30-100-300-500-1000 mA – VAR
    • 10-30-100 mA
    • Multiplier:
      • x ½, x 1
      • x 5
    • Measurement range
      • RCD Type G
        • 310 ms
        • 50 ms
      • RCD Type S
        • 510 ms
        • 160 ms
    • Notes:
      • ¹1000 mA type AC only
      • 700 mA maximum type A in VAR mode
      • VAR mode not available for type B.
  • RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
    • Current range:  30% to 110% of RCD rated current¹
    • Step size: 10% of IΔN²
    • Dwell time:
      • Type G 300 ms/step
      • Type S 500 ms/step
    • Measurement: accuracy ±5%
    • Specified trip current ranges (EN 61008-1) :
      • 50% to 100% for Type AC
      • 35% to 140% for Type A (>10 mA)
      • 35% to 200% for Type A (≤10 mA)
      • 50% to 200% for Type B
      • ²5% for Type B
    • Notes
      • ¹30% to 150% for Type A IΔN > 10 mA
      • 30% to 210% for Type A IΔN = 10 mA
      • 20% to 210% for Type B
  • Earth Resistance Test (RE)
    • Range: 200 Ω / 2000 Ω
    • Resolution: 0.1 Ω / 1Ω
    • Frequency: 128 Hz
    • Output Voltage: 25 V
  • Phase Sequence Indication
    • Icon: icon phase sequence indicator Phase Sequence indicator is active.
  • Size (L x W x H):  10 x 25 x 12.5 cm
  • Weight (incl. batteries): 1.3 Kg
  • Battery size, quantity: Type AA, 6 ea.
  • Sealing IP-40
  • Safety: Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
  • Overvoltage: CAT III / 500V; CAT IV 300V
  • Performance: EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

Includes:

  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • User's manual on CD-ROM